National Cancer Institute Home at the National Institutes of Health | www.cancer.gov
Please wait while this form is being loaded....
The Applied Research Program Web site is no longer maintained. ARP's former staff have moved to the new Healthcare Delivery Research Program, the Behavioral Research Program, or the Epidemiology & Genetics Research Program, and the content from this Web site is being moved to one of those sites as appropriate. Please update your links and bookmarks!

Publication Abstract

Authors: Lee JK, Liles EG, Bent S, Levin TR, Corley DA

Title: Accuracy of fecal immunochemical tests for colorectal cancer: systematic review and meta-analysis.

Journal: Ann Intern Med 160(3):171-

Date: 2014 Feb 04

Abstract: BACKGROUND: Performance characteristics of fecal immunochemical tests (FITs) to screen for colorectal cancer (CRC) have been inconsistent. PURPOSE: To synthesize data about the diagnostic accuracy of FITs for CRC and identify factors affecting its performance characteristics. DATA SOURCES: Online databases, including MEDLINE and EMBASE, and bibliographies of included studies from 1996 to 2013. STUDY SELECTION: All studies evaluating the diagnostic accuracy of FITs for CRC in asymptomatic, average-risk adults. DATA EXTRACTION: Two reviewers independently extracted data and critiqued study quality. DATA SYNTHESIS: Nineteen eligible studies were included and meta-analyzed. The pooled sensitivity, specificity, positive likelihood ratio, and negative likelihood ratio of FITs for CRC were 0.79 (95% CI, 0.69 to 0.86), 0.94 (CI, 0.92 to 0.95), 13.10 (CI, 10.49 to 16.35), 0.23 (CI, 0.15 to 0.33), respectively, with an overall diagnostic accuracy of 95% (CI, 93% to 97%). There was substantial heterogeneity between studies in both the pooled sensitivity and specificity estimates. Stratifying by cutoff value for a positive test result or removal of discontinued FIT brands resulted in homogeneous sensitivity estimates. Sensitivity for CRC improved with lower assay cutoff values for a positive test result (for example, 0.89 [CI, 0.80 to 0.95] at a cutoff value less than 20 µg/g vs. 0.70 [CI, 0.55 to 0.81] at cutoff values of 20 to 50 µg/g) but with a corresponding decrease in specificity. A single-sample FIT had similar sensitivity and specificity as several samples, independent of FIT brand. LIMITATIONS: Only English-language articles were included. Lack of data prevented complete subgroup analyses by FIT brand. CONCLUSION: Fecal immunochemical tests are moderately sensitive, are highly specific, and have high overall diagnostic accuracy for detecting CRC. Diagnostic performance of FITs depends on the cutoff value for a positive test result. PRIMARY FUNDING SOURCE: National Institute of Diabetes and Digestive and Kidney Diseases and National Cancer Institute.

Last Modified: 03 Sep 2013